Call Us Now !
Power Supply Unit with Battery Backup • 12VDC 3A UPS • with Battery Compartment for 7Ah Battery (Battery NOT Included) [PSU CCTV 12VDC 3A]
Power Supply Unit with Battery Backup • 12VDC 3A UPS • with Battery Compartment for 7Ah Battery (Battery NOT Included) [PSU CCTV 12VDC 3A] Power Supply Unit with Battery Backup • 12VDC 3A UPS • with Battery Compartment for 7Ah Battery (Battery NOT Included) [PSU CCTV 12VDC 3A]

12V CCTV Power Supply

CCTV / 12VDC / 3A Power Supply
Battery NOT Included
Power Supply Unit with Battery Backup • 12VDC 3A UPS • with Battery Compartment for 7Ah Battery (Battery NOT Included)
Part No: PSU CCTV 12VDC 3A
Discontinued
Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE

Features

  • Input voltage can vary from 90VAC to 265VAC without affecting the output voltage. (output voltage remains constant)
  • Input and output fused
  • Short circuit protected
  • Overload protected (resettable fuse)
  • Reverse polarity protected
  • Low voltage battery trip (Battery will cut out when voltage falls below 10V)
  • Input mains filtration surge, and lightning pmtected.
  • All operations are automatic,( in case of a power Inlure the supply will switch to battery,when the supply returns it will automatically retum to normal state)
  • Mains Fail Output Facility
  • Neat looking PVC flame retardant housing (Custom designed lur the powermax powerpack range)
  • The red output wire of power supplies is connected with red pin of battery.
  • The black output wire of power supplies is connected with black pin of battery.

Specifications

  • Input voltage range : 90VAC to 265VAC
  • Input frequency range :47Hz to 63Hz
  • Inrush current : 60 Amp max
  • Input current : 800ma at full load
  • Power supply efficiency : > 75%
  • Output no load voltage : < 14VDC
  • Battery charger output : 13.8VDC ± 1%
  • Output Current : 2200mA
  • Battery charger current : 1000mA
  • Total power supply current : 3200mA
  • Over voltage protection : (The supply shall shut down if output voltage exceeds 16V)
  • Operating temperature : 49°C at continious full load
  • Insulation resistance (primary to secondary) : 30Meg ohm
  • Hi-Pot Test (primary to secondary) : 3600V for 3 seconds

Downloads


Copyright © 2024, Communica (Pty) Ltd.

Communica is a wholesale and retail distributor of semiconductors, electromechanical and passive electronic components for automotives, electronics, electrical, automation, mining and process control industries and technical and tertiary educational institutions. We also offer a large range of security and CCTV equipment, power supplies, test instruments and accessories, tools and production equipment, prototyping platforms, and hobby and educational products.