Catalog > Test and Measurement > Test and Measurement Instruments > Multimeters > Digital Multimeters Catalog > Test and Measurement > Test and Measurement Instruments > Fluke Instruments Catalog > Test and Measurement > Test and Measurement Instruments > UNI-T Instruments Fluke Pocket Size Digital Multimeter Digital Pocket Multimeter FLUKE 107 Palm-Sized Compact Digital Multimeter, Measures 600VAC/DC, 10A AC/DC, 40M Resistance, Diode, 1000uF Capacitance, Datas Hold 6000 Counts, 100KHz FREQ & Duty Cycle, Backlight 142X69X28mm 2,464.87 ZAR inc for 1 Each 3 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Overview The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry. Features Fluke 107 measurement test functions AC and DC voltage AC and DC current Resistance Capacitance Diode Frequency and duty-cycle Fluke 107 comes ready to workThe Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing. Specifications Precision specifications AC voltage(40 Hz to 500 Hz)1 Range Resolution Accuracy 6.000 V60.00 V600.0 V 0.001 V0.01 V0.1 V 1.0 % + 3 DC voltage 6.000 V60.00 V600.0 V 0.001 V0.01 V0.1 V 0.5 % + 3 Exchange millivolts 600.0 mV 0.1 mV 3.0 % + 3 Diode test2 2.000 V 0.001 V 10 % Resistance(ohm) 400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ 0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ 0.5 % + 30.5 % + 20.5 % + 20.5 % + 20.5 % + 21.5% + 3 Capacitor3 50.00 nF500.0 nF5.000 μF50.00 μF500.0 μF1000 μF 0.01 nF0.1 nF0.001 μF0.01 μF0.1 μF1 μF 2 % + 52 % + 55 % + 55 % + 55 % + 55 % + 5 Frequency4 Hz(10 Hz – 100 kHz) 50.00 Hz500.0 Hz5.000 kHz50.00 kHz100.0 kHz 0.01 Hz0.1 Hz0.001 kHz0.01 kHz0.1 kHz 0.1 % + 3 Duty cycle4 1 % to 99 % 0.10 % 1 % typical case5 AC current(40 Hz - 200 Hz) 4.000 A10.00 A 0.001 A0.01 A 1.5 % + 3 DC 4.000 A10.00 A 0.001 A0.01 A 1.5 % + 3 All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range). All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%. Features Overload protection Input impedance (nominal value) Common mode rejection ratio Normal mode rejection ratio AC voltage 600 V 1 >10 MΩ <100 pF 2 >60 dB at 50 Hz or 60 Hz at DC current − Exchange millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz − DC voltage 600 V 1 >10 MΩ <100 pF >100 dB at 50 Hz or 60 Hz at DC current >60 dB at 50 Hz or 60 Hz Up to 6 x 105 V Hz For medium voltage (alternating current), the input impedance is approximately 1 MΩ. General technical indicators The highest voltage applied to any terminal and ground 600 V Display (LCD) 6000 counts, updated three times per second Type of battery Two AAA batteries (NEDA 24A, IEC LR03) Battery life At least 200 hours Temperature Operating temperature 0 °C to 40 °C Storage temperature -30 °C to 60 °C Relative humidity Working humidity No condensation below 10 °C≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C Working humidity, 40 MΩ range ≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C Altitude Working elevation 2000 m Storage altitude 12,000 m Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) Current input fuse protection 11A, 1000V fast-melting type, must use Fluke designated parts Volume (height x width x length) 142 mm x 69 mm x 28 mm Weight 200 g Protection level IEC 60529: IP 40 Safety IEC 61010-1: 600 V CAT III, pollution degree 2 Electromagnetic environment IEC 61326-1: Portable Electromagnetic compatibility Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1 1 This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment. Downloads User Manual Fluke 106 - 107 PDF File 886.36 KB Datasheet - FLUKE 107 PDF File 1.19 MB