Catalog > Electro-Mechanical Components > Connectors > Interface Connectors > Industrial Ground Fault Module Ground Fault Module 3UF7510-1AU00-0 Ground Fault Module with Analog Residual Current Detection for Connection of a Residual-Current Transformer 7,348.88 ZAR inc for 1 Each 0 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Specifications General technical data type of current for monitoring AC and pulse-shaped direct currents (type A) response time maximum 100 ms product component ● input for thermistor connection No ● input for analog temperature sensors No ● input for ground fault detection Yes consumed active power 0.1 W protection class IP IP20 shock resistance according to IEC 60068-2-27 15g / 11 ms vibration resistance according to IEC 60068-2-6 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g Substance Prohibitance (Date) 05/01/2012 measurable line frequency initial value 400 Hz measurable line frequency full-scale value 16 Hz relative measurement deviation of residual current transformer 2.5 % Electromagnetic compatibility EMC emitted interference according to IEC 60947-1 class A EMC immunity according to IEC 60947-1 corresponds to degree of severity 3 conducted interference ● due to burst according to IEC 61000-4-4 1 kV ● due to conductor-earth surge according to IEC 61000-4-5 2 kV ● due to conductor-conductor surge according to IEC 61000-4-5 1 kV ● due to high-frequency radiation according to IEC 61000-4-6 10 V field-based interference according to IEC 61000-4-3 10 V/m electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge field-bound HF interference emission according to CISPR11 corresponds to degree of severity A Inputs/ Outputs number of inputs 1 number of digital inputs 0 number of analog inputs 1 number of sensor inputs for ground fault detection 1 number of outputs 0 number of semiconductor outputs 0 number of outputs as contact-affected switching element 0 number of analog outputs 0 Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting height 92 mm width 22.5 mm depth 124 mm required spacing ● top 40 mm ● bottom 40 mm ● left 0 mm ● right 0 mm diameter of inlet opening of connectable residual current transformer 35 ... 210 mm Connections/ Terminals type of connectable conductor cross-sections ● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) ● finely stranded with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● at AWG cables solid 1x (20 ... 14), 2x (20 ... 16) ● at AWG cables stranded 1x (20 ... 12), 2x (20 ... 14) tightening torque with screw-type terminals 0.8 ... 1.2 N·m tightening torque [lbf·in] with screw-type terminals 7 ... 10.3 lbf·in Ambient conditions installation altitude at height above sea level ● 1 maximum 2 000 m ● 2 maximum 3 000 m; max. +50 °C (no protective separation) ● 3 maximum 4 000 m; max. +40 °C (no protective separation) ambient temperature ● during operation -25 ... +60 °C ● during storage -40 ... +80 °C ● during transport -40 ... +80 °C environmental category ● during operation according to IEC 60721 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 ● during storage according to IEC 60721 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4 ● during transport according to IEC 60721 2K2, 2C1, 2S1, 2M2 relative humidity during operation 5 ... 95 % Safety related data touch protection against electrical shock finger-safe Downloads Datasheet - 3UF7510-1AU00-0 PDF File 389.07 KB