Catalog > Test and Measurement > Test and Measurement Instruments > Special Function Testers > Miscellaneous Testers Three Phase Energy Logger Three Phase Energy Logger ME440 ENERGY ANALYZER THREE PHASE ENERGY LOGGER, ENERGY ANALYZER, ELECTRICAL NETWORK ANALYZER, POWER QUALITY ANALYZER, ENERGY METER 21,808.69 ZAR inc for 1 Each 2 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Specifications Specification Model ME440 Product component type Handheld;poly-phase;data logger;power analyzer Poles description 3PH4W 3PH3W 1PH2W (L-N); 1PH2W(L-L);1PH3W(L-L-N) Device application Power analysis Data log Input type External Rogowski coil External CT(333mV only) Display 3.5 inch TFT screen display Sampling rate 8k samples per second Harmonic 51th in the mean time Mechanical characteristics Weight 850g (with Accessory 2kgs) Dimension L*W*D:21.5*13*6CM Characteristics Description Current Per phase, neutral, and average of 3 phases Voltage L-L, L-N, and average of 3 phases,N-PE Frequency 45...65 Hz Active power Total and per phase (signed) Reactive power Total and per phase (signed) Apparent power Total and per phase(signed) Power factor (True) Total and per phase0.000 to 1 (signed) Angle Voltage angle,Current angle Current unbalance Per phase, most unbalanced of 3 phases Voltage unbalance most unbalanced of 3 phases Characteristics Description Current Per phase and average Voltage per phase and average Active power Per phase and total Reactive power Per phase and total Apparent power Per phase and total Characteristics Description Current Per phase and average Active, reactive, apparent power Per phase and Total Peak Demand Values Current Per phase and average Active, reactive, apparent power Per phase and Total Characteristics Description Energy values Active energy 0 to 999.9GWhAuto reset to 0 in case of over limit Reactive energy 0 to 999.9GVARhAuto reset to 0 in case of over limit Apparent energy 0 to 999.9GVAhAuto reset to 0 in case of over limit Characteristics Description THD Total,2,3,4,5,,,,,51(51 times) Per phase current (percentage value) X,Y,Z,A,B(5 times each time) Per phase current(rms value) Total,2,3,4,5,,,51(51 times)Per phase voltage(percentage value) X,Y,Z,A,B(5 times each time)Per phase voltage(rms value) Downloads Datasheet - ME440 ENERGY ANALYZER PDF File 2.34 MB