Catalog > Test and Measurement > Test and Measurement Instruments > Special Function Testers > Miscellaneous Testers Victron MultiPlus-II Inverter/Charger Inverter VICT MULTIPLUS-II 24/3000/70-32 Victron multiplus-ii inverter/charger 2400W 230VAC , MAX AC I/P Current:50A , DC I/P Voltage: 19-33V , MAX AC I/P Voltage:187-265VAC , IP22 , M8 Bolts , 499x268x141 , 19kg 19,095.00 ZAR inc for 1 Each 0 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Features A MultiPlus, plus ESS (Energy Storage System) functionality The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an externalcurrent sensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications. It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.Several system configurations are possible. For more detailed information see the ESS Design and configuration manual. PowerControl and PowerAssist - Boosting the capacity of the grid or a generator A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and usewhatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControlfunction). PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for alimited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.When the load reduces, the spare power is used to recharge the battery. Solar energy: AC power available even during a grid failure The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It iscompatible with both solar charger controllers and grid-tie inverters. Two AC Outputs The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event ofa grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) thatcomputers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge thebattery, like a water heater for example, can be connected to this output. Virtually unlimited power thanks to parallel (not for the 8k, 10k and 15k models) and three phase operation Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide25 kW / 30 kVA output power with 420 Amps charging capacity. In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s notall: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps chargingcapacity. On-site system configuring, monitoring and control Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interfaceneeded). Several monitoring and control options are available: Cerbo GX, Color Control GX, Venus GX, Octo GX, CANvu GX, laptop,computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel. Remote configuring and monitoring Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed. Specifications INVERTER DC Input voltage range :12V - 9,5–17 V 24V - 19–33V 48V – 38-66 V Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1) Cont. output power at 25°C (3): 3000 VA Cont. output power at 25°C; 2400 W Cont. output power at 40°C :2200 W Cont. output power at 65°C :1700 W Max apparent feed-in power :3000 VA Peak power: 5500 W Maximum efficiency: 93%/94%/95% Zero load power: 13 / 13 / 11 W Zero load power in AES mode :9 / 9 / 7 W Zero load power in Search mode: 3 / 3 / 2 W CHARGER AC Input : Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Charge voltage 'absorption': 14,4 / 28,8 / 57,6 V Charge voltage 'float' :13,8 / 27,6 / 55,2 V Storage mode: 13,2 / 26,4 / 52,8 V Max. battery charge current: (4) 120 /70 / 35 A Battery temperature sensor: Yes GENERAL Auxiliary output :Yes (32A) External AC current sensor (optional):50A or 100A Programmable relay (5) : Yes Protection (2): a – g VE.Bus communication port : For parallel (not for 8k, 10k and 15k models) and three phase operation, remote monitoring and system integration General purpose com. port: Yes, 2x Remote on-off: Yes Operating temperature range: -40 to +65°C (fan assisted cooling) Humidity (non-condensing) : max 95% ENCLOSURE Material & Colour : Steel, blue RAL 5012 Protection category: IP22 Battery-connection: M8 bolts 230 V AC-connection: Screw terminals 13 mm2 (6 AWG) Weight : 19 kg Dimensions (hxwxd) mm: 546 x 275 x 147 499 x 268 x 141 499 x 268 x 141 STANDARDS Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 Emission, Immunity: EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 610 00-6-1, IEC 61000-6-2, IEC 61000-6-3 Uninterruptible power supply: Please consult the certificates on our website. Anti-islanding: Please consult the certificates on our website. Downloads Datasheet - VICT MULTIPLUS-II 24/3000/70-32 PDF File 573.68 KB