Catalog > Electro-Mechanical Components > Industrial Automation Schneider Converter for Optimum PT100 Probes for Optimum PT100 Probes Converter RMPT73BD Schneider Converter for Optimum Pt100 probes, Harmony Analog, temperature transmitter, 0 - 500 degree C. Discontinued Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Specifications Main Range of product Harmony Analog Product or component type Converter for Optimum Pt100 probes Analogue input type Temperature probe 0...500 °C/32...932 °F Pt 100 2, 3 or 4 wires Analogue output type Current 4...20 mA <= 500 OhmVoltage 0...10 V >= 100 kOhm Complementary Protection type Overvoltage protection on output (+/- 30 V)Reverse polarity protection on power supplyShort-circuit protection on outputReverse polarity protection on output abnormal analogue output voltage -15...-11 V when no input or input wire broken11...15 V when no input or input wire broken abnormal analogue output current -30…0 mA when no input or input wire broken22…30 mA when no input or input wire broken [Us] rated supply voltage 24 V DC non isolated +/- 20 % Current consumption <= 40 mA for voltage output<= 60 mA for current output Local signalling LED (green) for power ON Measurement error +/- 0.5 % of full scale (3 or 4 wires) at 20 °C+/- 1 % of full scale (2 wires) at 20 °C+/- 10 % of full scale at 20 °C (electromagnetic interference of 10 V/m) Repeat accuracy +/- 0.2 % full scale at 20 °C+/- 0.6 % full scale at 60 °C Temperature coefficient 150 ppm/°C Maximum wiring resistance 0.2 Ohm connection in 2 wires clamping connection capacity 2 x 1.5 mm²1 x 2.5 mm² tightening torque 0.6…1.1 N.m Marking CE Surge withstand 0.5 kV during 1.2/50 µs conforming to IEC 61000-4-5 [Ui] rated insulation voltage 2000 V Fixing mode Clip-on (35 mm symmetrical DIN rail)Fixed (mounting plate) Safety reliability data MTTFd = 43.9 yearsB10d = 40564 Net weight 0.12 kg Environment Electromagnetic compatibility Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Standards DIN 43760EN/IEC 60584-1EN/IEC 60947-1EN/IEC 60751 Product certifications GLULCSA IP degree of protection IP20 (terminal block)IP50 (housing) Fire resistance 850 °C conforming to IEC 60695-2-1850 °C conforming to UL Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27 Vibration resistance 5 gn (f= 10…100 Hz) conforming to IEC 60068-2-6 Resistance to fast transients 1 kV (on input-output) conforming to IEC 61000-4-42 kV (on power supply) conforming to IEC 61000-4-4 Disturbance radiated/conducted CISPR 11CISPR 22 group 1 - class B Ambient air temperature for storage -40…85 °C Ambient air temperature for operation 0…50 °C mounting side by side0…60 °C 2 cm spacing Pollution degree 2 conforming to IEC 60664-1 Downloads Datasheet - RMPT73BD PDF File 177.56 KB