Catalog > Consumer Electronics > Computer Peripherals > Computer Adaptors > Others Catalog > Electro-Mechanical Components > Industrial Automation Basic unit SIMOCODE pro C SIRIUS 3UF7000-1AU00-0 Basic Unit SIMOCODE pro C, PROFIBUS DP Interface 12 Mbit/s, RS 485, 4I/3O Freely Parameterizable, Us: 110...240 V AC/DC, Input for Thermistor Connection Monostable Relay Outputs 8,272.64 ZAR inc for 1 Each 2 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Specifications Basic unit SIMOCODE pro C, PROFIBUS DP interface 12 Mbit/s, RS 485, 4I/3O freely parameterizable, Us: 110...240 V AC/DC, input for thermistor connection Monostable relay outputs product brand name SIRIUS product designation Motor management system design of the product basic unit 1 product type designation SIMOCODE pro C General technical data product function ● bus communication Yes ● data acquisition function Yes ● diagnostics function Yes ● password protection Yes ● test function Yes ● maintenance function Yes product component ● input for thermistor connection Yes ● digital input Yes ● input for analog temperature sensors No ● input for ground fault detection No ● relay output Yes product extension ● temperature monitoring module No ● current measuring module Yes ● current/voltage measuring module No ● fail-safe digital I/O module No ● ground-fault monitoring module No ● control unit with display No ● control unit Yes ● analog I/O module No apparent power consumption 5.3 VA consumed active power 2.9 W insulation voltage with degree of pollution 3 at AC rated value 300 V surge voltage resistance rated value 4 000 V protection class IP IP20 shock resistance ● according to IEC 60068-2-27 15g / 11 ms ● vibration resistance 1-6 Hz / 15 mm; 6-500 Hz / 2 g switching capacity current of the NO contacts of the relay outputs at AC-15 ● at 24 V 6 A ● at 120 V 6 A ● at 230 V 3 A switching capacity current of the NO contacts of the relay outputs at DC-13 ● at 24 V 2 A ● at 60 V 0.55 A ● at 125 V 0.25 A mechanical service life (switching cycles) typical 10 000 000 electrical endurance (switching cycles) typical 100 000 buffering time in the event of power failure 0.05 s reference code according to IEC 81346-2 F continuous current of the NO contacts of the relay outputs ● at 50 °C 6 A ● at 60 °C 5 A type of input characteristic Type 1 in accordance with EN 61131-2 Substance Prohibitance (Date) 05/01/2012 certificate of suitability ● according to ATEX directive 2014/34/EU BVS 06 ATEX F001 explosion device group and category according to ATEX directive 2014/34/EU II (2) G, II (2 ) D, I (M2) Electromagnetic compatibility EMC emitted interference according to IEC 60947-1 class A EMC immunity according to IEC 60947-1 corresponds to degree of severity 3 conducted interference ● due to burst according to IEC 61000-4-4 2 kV (power ports) / 1 kV (signal ports) ● due to conductor-earth surge according to IEC 61000-4-5 2 kV ● due to conductor-conductor surge according to IEC 61000-4-5 1 kV ● due to high-frequency radiation according to IEC 61000-4-6 10 V field-based interference according to IEC 61000-4-3 10 V/m electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge conducted HF interference emissions according to CISPR11 corresponds to degree of severity A field-bound HF interference emission according to CISPR11 corresponds to degree of severity A Inputs/ Outputs product function ● parameterizable inputs Yes ● parameterizable outputs Yes number of inputs 4 ● for thermistor connection 1 number of digital inputs with a common reference potential 4 digital input version type 1 acc. to IEC 61131 Yes input voltage at digital input at DC rated value 24 V number of outputs 3 number of semiconductor outputs 0 number of outputs as contact-affected switching element 3 switching behavior monostable type of relay outputs Monostable wire length for digital signals maximum 300 m wire length for thermistor connection ● with conductor cross-section = 0.5 mm² maximum 50 m ● with conductor cross-section = 1.5 mm² maximum 150 m ● with conductor cross-section = 2.5 mm² maximum 250 m Protective and monitoring functions product function ● asymmetry detection Yes ● blocking current evaluation Yes ● power factor monitoring No ● ground fault detection Yes ● phase failure detection Yes ● phase sequence recognition No ● voltage detection No ● monitoring of number of start operations Yes ● overvoltage detection No ● overcurrent detection 1 phase Yes ● undervoltage detection No ● undercurrent detection 1 phase Yes ● active power monitoring No product function ● current detection Yes ● overload protection Yes ● evaluation of thermistor motor protection Yes total cold resistance number of sensors in series maximum 1.5 kΩ response value of thermoresistor 3 400 ... 3 800 Ω ● of the short-circuit control 9 Ω release value of thermoresistor 1 500 ... 1 650 Ω Motor control functions product function ● parameterizable overload relay Yes ● circuit breaker control Yes ● direct start Yes ● reverse starting Yes ● star-delta circuit No ● star-delta reversing circuit No ● Dahlander circuit No ● Dahlander reversing circuit No ● pole-changing switch circuit No ● pole-changing switch reversing circuit No ● slide control No ● valve control No Communication/ Protocol ● protocol is supported PROFIBUS DP protocol Yes ● protocol is supported PROFINET IO protocol No ● protocol is supported PROFIsafe protocol No ● protocol is supported Modbus RTU No ● protocol is supported EtherNet/IP No ● protocol is supported OPC UA Server No ● protocol is supported LLDP No ● protocol is supported Address Resolution Protocol (ARP) No ● protocol is supported SNMP No ● protocol is supported HTTPS No ● protocol is supported NTP No ● protocol is supported Media Redundancy Protocol (MRP) No ● product function is supported Device Level Ring (DLR) No number of interfaces ● according to PROFINET 0 ● according to PROFIBUS 1 ● according to Ethernet/IP 0 product function ● web server No ● shared device No ● at the Ethernet interface Autocrossover No ● at the Ethernet interface Autonegotiation No ● at the Ethernet interface Autosensing No ● is supported PROFINET system redundancy No ● supports PROFIenergy measured values No ● supports PROFIenergy shutdown No transfer rate maximum 12 Mbit/s identification & maintenance function ● I&M0 - device-specific information Yes ● I&M1 – higher level designation/location designation Yes ● I&M2 - installation date Yes ● I&M3 - comment Yes type of electrical connection of the communication interface 9-pin SUB-D socket (12 Mbit) / screw terminal (1.5 Mbit) Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting height 111 mm width 45 mm depth 95 mm required spacing ● top 40 mm ● bottom 40 mm ● left 0 mm ● right 0 mm Connections/ Terminals product component removable terminal for auxiliary and control circuit Yes type of connectable conductor cross-sections ● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) ● finely stranded with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● at AWG cables solid 1x (20 ... 12), 2x (20 ... 14) ● at AWG cables stranded 1x (20 ... 14), 2x (20 ... 16) tightening torque with screw-type terminals 0.8 ... 1.2 N·m tightening torque [lbf·in] with screw-type terminals 7 ... 10.3 lbf·in type of connectable conductor cross-sections for PROFIBUS wire 2x 0.34 mm², AWG 22 Ambient conditions installation altitude at height above sea level ● 1 maximum 2 000 m ● 2 maximum 3 000 m; max. +50 °C (no protective separation) ● 3 maximum 4 000 m; max. +40 °C (no protective separation) ambient temperature ● during operation -25 ... +60 °C ● during storage -40 ... +80 °C ● during transport -40 ... +80 °C environmental category ● during operation according to IEC 60721 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 ● during storage according to IEC 60721 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4 ● during transport according to IEC 60721 2K2, 2C1, 2S1, 2M2 relative humidity ● during operation 5 ... 95 % contact rating of auxiliary contacts according to UL B300 / R300 Short-circuit protection design of short-circuit protection per output Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) Safety related data touch protection against electrical shock finger-safe Galvanic isolation (electrically) protective separation according to IEC 60947-1 All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) Control circuit/ Control product function soft starter control No type of voltage of the control supply voltage AC/DC control supply voltage at AC ● at 50 Hz rated value 110 ... 240 V ● at 60 Hz rated value 110 ... 240 V control supply voltage frequency ● 1 rated value 50 Hz ● 2 rated value 60 Hz relative symmetrical tolerance of the control supply voltage frequency 5 % control supply voltage at DC ● rated value 110 ... 240 V operating range factor control supply voltage rated value at DC ● initial value 0.85 ● full-scale value 1.1 operating range factor control supply voltage rated value at AC at 50 Hz ● initial value 0.85 ● full-scale value 1.1 operating range factor control supply voltage rated value at AC at 60 Hz ● initial value 0.85 ● full-scale value 1.1 inrush current peak ● at 240 V 3 A duration of inrush current peak ● at 240 V 1 ms Downloads Datasheet - 3UF7000-1AU00-0 PDF File 492.58 KB