Catalog > Passive Components > Sensors - Transducers Signal Conditioner Sensor Signal Conditioner Sensor S2A LVDT Signal Conditioner Sensor DIN Rail 24VDC (15-30VDC) 6 Stepped DC Outputs -10 - + 10V /0-20mA/4-20mA. LVDT Range 50 - 5,000 mVRMS. -20 to +75°C. 15,087.90 ZAR inc for 1 Each 0 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Features Functional Features: Cybersecurity lock to prevent tampering Smart calibration by front panel push buttons Color-coded screw terminal plugs Auto-mastering Hot swapability Differential input for superior noise immunity Real-time recalibration Diagnostic Features: Shorted, disconnected, or open primary Shorted, grounded, disconnected, or open secondaries Output voltage shorts or current loop opens Errors during installation and setup Specifications Operating Power: +15 to +30 V DC (+24 V nominal), 100 mA max. at 24 V DC; +15 V DC and –15 V DC needed for ±10 V DC bipolar output Analog DC Outputs: 0 - 5 V, 1 - 5 V, 0.5 - 4.5 V, 0.5 - 9.5 V, 0 - 10 V, -10 to +10 V, 0-20 mA sourcing (3-wire), 4-20 mA sourcing (3-wire) Loop Resistance : 850 Ohms maximum with 24 V DC supply Output Non-Linearity : ≤±0.025% of Full Span Output (FSO) Operating Temperature : -20 to 75 C Noise and Ripple : ≤1 mVrms (voltage output); ≤2 μArms (current loop output) Temperature coefficient : ±0.0025% of FSO/deg C (combined span and zero shift) Excitation Frequencies : 1 kHz, 3 kHz, 5 kHz, 10 kHz (nominal) LVDT Output Range : 50 to 5000 mVrms at LVDT’s full scale position Excitation Voltage : 3.0 Vrms (nominal) push-pull drive (factory default) 4.5 Vrms (nominal) push-pull drive (jumper J7 removed) 1.5 Vrms (nominal) single-ended drive for low impedance primary Auto-Master Syncing : Master output controls up to fifteen slave units Fault Detection : Open LVDT winding, shorted or grounded LVDT connection, cable disconnected, voltage output shorted or current loop open Failure Indications : Front panel LEDs; output out of range; NO/NC open-collector switch Null Detection : Front panel LEDs; ±3 V DC max. floating null output signal Zero Set : Front panel push button or RS-485 ASCII command Full Scale Set : Front panel push button or RS-485 ASCII command Digital Interface : RS-485 2-wire multi-drop network, 16 individual addresses Cybersecurity Lock : User enabled Downloads Datasheet - S2A PDF File 1.25 MB