Catalog > Consumer Electronics > Security & Alarms > Paradox Alarms Hub and Bus Isolator Hub Bus Isolator PDX PA5363 PARADOX HUB2 , HUB AND BUS ISOLATOR (PA5363) Discontinued Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Overview The APR3-HUB2 is a non-addressable module that extends and divides the control panel’s bus into two completely isolated bus outputs (two for each connected APR3-HUB2). It extends the combus/communication bus by regenerating the signal between the control panel and its modules. Should one bus output experience trouble or tampering, the other will remain unaffected. The hub monitors the signal between the control panel and modules on each output. If the hub detects a loss of signal integrity it will cut off the troubled output until proper communication is reestablished. Specifications Power Input : Typically 12-16VdcCurrent Consumption : Typically 24mA. (50mA max)Distance from Panel : Digiplex (DGP-848/DGP-NE96): 18AWG = 914m (3000ft) or 22AWG = 305m (1000ft)Spectra: 18AWG or 22AWG = 76m (250ft)Distance of each Output : Digiplex (DGP-848/DGP-NE96) : 18AWG = 914m (3000ft) or 22AWG = 305m (1000ft)Spectra : 18AWG or 22AWG = 76m (250ft)Operating Temperature : -20°C to 50°C (-4°F to 122°F)Compatibility : Any Spectra or Digiplex (DGP-848, DGP-NE96) control panel Downloads Datasheet - PDX PA5363 PDF File 288.56 KB