Catalog > Test and Measurement > Test and Measurement Instruments > Special Function Testers > Digital Clamp Meters Non-Contact Voltage Digital Clamp Meter Clamp Meter FLUKE 378FC Digital Clamp Meter Non-Contact Voltage True RMS 1000V AC/DC with IFLEX, Max Resistance:60kΩ, Max Jaw Opening:34mm, CAT III 1000V, CATIV 600V 23,181.90 ZAR inc for 1 Each 0 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Features Measure voltage and current with your clamp jaw Faster, safer testing – all without touching a live wire – using FieldSense™ technology Power quality indicator shows whether equipment or power line is faulty Complete 3-phase voltage and current tests in 3 quick steps Specifications General specifications General Maximum Voltage between any Terminal and Earth Ground 1000 V Battery Type 2 AA IEC LR6 alkaline Life 200 hour Display Dual readout Automatic Power Off 20 minutes Electrical AC Current: Jaw Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits (45 Hz to 66 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 AC Current: Flexible Current Probe Range 2500 A Resolution 1 A (≤2500 A) 0.1 A (≤999.9 A) Accuracy 3 % ±5 digits (5 Hz to 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2 % ±10 digits1 [1]When using the ZERO function to compensate for offsets AC Voltage: Field Sense Range 1000 V Resolution 1 V (≤1000V) Accuracy ≤4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz) ≥4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz) Position wire as close as possible to jaw opening (see illustration). AC Voltage: Test Leads Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits (20 Hz to 500 Hz) DC Voltage Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±10 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1 % ±5 digits Amps Frequency: Jaw Range 45 Hz to 66 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A Amps Frequency: Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz,≥25 A Resistance Range 60.00 kΩ 6000 Ω 600.0 Ω Resolution 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) Accuracy 1 % ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) Accuracy 1 % ±4 digits Mechanical Size (L x W x H) 274 mm x 86 mm x 47 mm Weight (with Batteries) 463 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Rogowski Coil Length 450 mm Environmental Operating Temperature -10 °C to 50 °C Storage Temperature -40 °C to 60 °C Operating Humidity (without condensation) Non condensing (<10 °C) ≤90 % RH (10 °C to 30 °C) ≤75 % RH (30 °C to 40 °C) ≤45 % RH (40 °C to 50 °C) Temperature Coefficients Add 0.1 x specified accuracy for each degree C >28 °C or <18 °C Ingress Protection IEC 60529: IP30 (jaw closed) Operating Altitude 2000 m Storage Altitude 12 000 m Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2, CISPR 11: Group 1, Class B Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Safety General IEC 61010-1: Pollution degree 2 Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V Current Clamp for Leakage Current Measurements IEC 61557-13: Class 2, ≤30 A/m Wireless Radio Radio Frequency Certification FCC ID: T68-FBLE IC:6627A-FBLE Frequency Range 2405 MHz to 2480 MHz Output Power <100 mW Radio Frequency Data Radio Frequency Data For Class A Devices SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://media.fluke.com/ef664f31-68ef-40d9-9ca7-b10800bf192b_original%20file.pdf. Downloads Datasheet - FLUKE 378FC PDF File 1.76 MB