Catalog > Test and Measurement > Test and Measurement Instruments > Multimeters > Digital Multimeters Thermocouple Temperature Calibrator Thermocouple Temperature Calibrator FLUKE 714B Thermocouple Temperature Calibrator, Millivolt Measurement & Source: -10mV~75mV, Range:0.01mV, 0.015 % + 10 µA, DC mA Measurement:0-24mA, RANGE:0.001mA, 0.010%+2 µA, MAX:30V, MIL-T-28800E, CLASS2, IP52 49,571.86 ZAR inc for 1 Each 0 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Overview Delivering outstanding performance, this thermocouple calibrator presents durability and reliability. The calibrator is compact, lightweight, and offers an easy-to-use push-button interface. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. Features The Fluke 714B is a compact, battery-powered tool designed to make thermocouple calibration fast and easy. Just pick it up and go—measure and source a wide range of thermocouple types, as well as millivolts, with confidence and accuracy. Need to calibrate a linear thermocouple transmitter? The Fluke 714B’s mV source function has you covered. You can also measure milliamps while sourcing temperature, and run quick, linearity checks with the built-in linear ramp and 25% step auto ramp features. With these capabilities, you can complete routine and advanced calibration tasks with just one device. Built for Calibration Pros—But Easy for Anyone Saves Your Settings – The intelligent shutdown feature remembers your test settings, so you can pick up right where you left off after powering back up. Ready When You Are – Rugged and reliable, with a backlit display for easy reading in any environment. Accurate and Trusted – Delivers one-year and two-year accuracy specifications and comes with a traceable certificate of calibration. Simple, Single-Function Design – The straightforward interface means you don’t have to spend time learning complicated menus. Just turn it on and start calibrating. Why Choose the Fluke 714B? If you want a high-accuracy, easy-to-use thermocouple calibrator you can trust for field or lab use, the Fluke 714B is the tool for you. It’s designed for busy calibration professionals who need results they can rely on, wherever the job takes them. Specifications Maximum voltage applied between any terminal and earth ground or between any two terminals 30 V Operating temperature -10°C to 50°C Storage temperature -30°C to 60°C Operating altitude 2,000 m Storage altitude 12,000 m Relative humidity (% RH operating without condensation) Non condensing90% (10°C to 30°C)75% (30°C to 40°C)45% (40°C to 50°C)(Without condensation) Vibration requirements MIL-T-28800E, Class 2 Drop text requirements 1 m IP Rating IEC 60529: IP52 Electromagnetic environment IEC 61326-1, Portable Safety IEC 61010-1, Max 30 V to earth, Pollution Degree 2 Power supply 4 AA NEDA 1.5A IEC LR6 batteries Size (H x W x L) 52.5 x 84 x 188.5 mm Weight 515 g DC mA Measurement Resolution Range Accuracy (% of reading + counts) 0-24 mA 0.001 mA 0.010% + 2 μA Temperature coefficient ±(0.002% of reading + 0.002% of range) /°C (< 18°C or > 28°C) Millivolt Measurement and Source Resolution Range Accuracy (% of reading +counts) -10 mV to 75 mV 0.01 mV 0.015% + 10 μA Temperature coefficient ±(0.002% of reading + 0.002% of range) /°C (< 18°C or > 28°C) Thermocouple Input and Output TC Type Range (°C) Measure (°C) Source (°C) 1 year 2 year 1 year 2 year E -250 to 200°C 1.3 2.0 0.6 0.9 -200 to -100°C 0.5 0.8 0.3 0.4 -100 to 600°C 0.3 0.4 0.3 0.4 600 to 1000°C 0.4 0.6 0.2 0.3 N -200 to -100°C 1.0 1.5 0.6 0.9 -100 to 900°C 0.5 0.8 0.5 0.8 900 to 1300°C 0.6 0.9 0.3 0.4 J -210 to -100°C 0.6 0.9 0.3 0.4 -100 to 800°C 0.3 0.4 0.2 0.3 800 to 1200°C 0.5 0.8 0.3 0.3 K -200 to -100°C 0.7 1.0 0.4 0.6 -100 to 400°C 0.3 0.4 0.3 0.4 400 to 1200°C 0.5 0.8 0.3 0.4 1200 to 1372°C 0.7 1.0 0.3 0.4 T -250 to -200°C 1.7 2.5 0.9 1.4 -200 to 0°C 0.6 0.9 0.4 0.6 0 to 400°C 0.3 0.4 0.3 0.4 B 600 to 800°C 1.3 2.0 1.0 1.5 800 to 1000°C 1.0 1.5 0.8 1.2 1000 to 1820°C 0.9 1.3 0.8 1.2 R -20 to 0°C 2.3 2.8 1.2 1.8 0 to 100°C 1.5 2.2 1.1 1.7 100 to 1767°C 1.0 1.5 0.9 1.4 S -20 to 0°C 2.3 2.8 1.2 1.8 0 to 200°C 1.5 2.1 1.1 1.7 200 to 1400°C 0.9 1.4 0.9 1.4 1400 to 1767°C 1.1 1.7 1.0 1.5 C 0 to 800°C 0.6 0.9 0.6 0.9 800 to 1200°C 0.8 1.2 0.7 1.0 1200 to 1800°C 1.1 1.6 0.9 1.4 1800 to 2316°C 2.0 3.0 1.3 2.0 L -200 to -100°C 0.6 0.9 0.3 0.4 -100 to 800°C 0.3 0.4 0.2 0.3 800 to 900°C 0.5 0.8 0.2 0.3 U -200 to 0°C 0.6 0.9 0.4 0.6 0 to 600°C 0.3 0.4 0.3 0.4 BP 0 to 1000°C 1.0 1.5 0.4 0.6 1000 to 2000°C 1.6 2.4 0.6 0.9 2000 to 2500°C 2.0 3.0 0.8 1.2 XK -200 to 300°C 0.2 0.3 0.2 0.5 300 to 800°C 0.4 0.6 0.3 0.6 G 100 to 300°C 1.6 2.4 1.2 1.8 300 to 1500°C 1.0 1.5 1.0 1.5 1500 to 2320°C 2.0 3.0 1.6 2.4 D 0 to 300°C 1.6 2.4 1.2 1.8 300 to 1500°C 1.0 1.5 1.0 1.5 1500 to 2315°C 2.0 3.0 1.6 2.4 P 0 to 1000°C 1.6 2.4 0.6 0.9 1000 to 1395°C 2.0 3.0 0.8 1.2 M -50 to 100°C 1.0 1.5 0.4 0.6 100 to 1000°C 1.6 2.4 0.6 0.9 1000 to 1410°C 2.0 3.0 0.8 1.2 Downloads Datasheet - FLUKE 714B PDF File 1.82 MB