Catalog > Consumer Electronics > Power Supplies > UPS MECER Online UPS 2U Rack Mount Online UPS 2U Rack Mount ME-3000-WPRU MECER Online UPS 2U Rack Mount 3000VA/2400W Transfer Time:4MS (Typical) , 6x12V9Ah Batteries, (630x483x88) 29.3KG, Support Windows2000/2003/XP/Vista/ 2008, Windows 7/8, Linux, Unix, and MAC 9,376.50 ZAR inc for 1 Each 1 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Features True double-conversion online UPS Wide input voltage range (110-300 VAC) Input power factor correction 0.99 Output power factor 0.8 Converter mode available ECO mode operation for energy saving (only available for 1-3KVA) Hot-swappable battery design only available for 1-3KVA Generator compatible Adjustable charging current via LCD or software (1A ~ 6A) Emergency power off function only available for 6K and up models Specifications INPUT Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%); 85-140VAC or 160-280VAC (Based on load at 100%) Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC Frequency Range 40Hz ~70 Hz Power Factor >= 0.99 @ Nominal Voltage (100% load) OUTPUT Voltage Regulation ± 1% Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz Transfer Time : AC Mode to Battery Mode Zero Transfer Time : Inverter to Bypass 4 ms (Typical) Transfer Time : Waveform (Batt. Mode) Pure Sine Wave Current Crest Ratio 3::1 Harmonic Distortion -- 3% THD (Linear Load); -- 6% THD (Non-linear Load) Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz EFFICIENCY Battery Mode 0.88 AC Mode 0.9 BATTERY Long-run Model : Battery Type Depending on the capacity of external batteries Long-run Model : Charging Current (max.) 1A/2A/4A/6A (Adjustable) Long-run Model : Charging Voltage 82.1 VDC ± 1% ,109.4 VDC ± 1% Long-run Model : Numbers 6, 8 Standard Model : Battery Type 12 V / 9 AH Standard Model : Charging Current (max.) 1A Standard Model : Charging Voltage 82.1 VDC ± 1% Standard Model : Numbers 6 Standard Model : Typical Recharge Time 4 hours recover to 90% capacity INDICATORS LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding ENVIRONMENT Operating Humidity 20~90% RH @ 0- 40°C (non-condensing) Noise Level Less than 50dB @ 1 Meter PHYSICAL Standard Model : Dimension, D x W x H (mm) 630 x 438 x 88 [2U] Standard Model : Net Weight (kgs) 29.3 Long-run Model : Dimension, D x W x H (mm) 410 x 438 x 88 [2U] Long-run Model : Net Weight (kgs) 14.2 MANAGEMENT Optional SNMP Power management from SNMP manager and web browser Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC Downloads Datasheet - ME-3000-WPRU PDF File 240.95 KB