Catalog > Electro-Mechanical Components > Industrial Automation Analog RTD And Thermocouple Module Analog RTD Thermocouple Module 1756-IR6I ControlLogix Input Module - Temperature - Isolated RTD inputs / Resistance Measurement 6 points (20P) Call for Price 0 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Features On-board data alarming Scaling to engineering units Real-time channel sampling Data format: Integer mode (left justified, 2 SEC complement) IEEE 32-bit floating point Module keying: Electronic software configurable RTB keying: User-defined mechanical Standards: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR, RUS_PAT_APPR, TUV-FS Specifications Number Of Channels : 6 (Isolated) Input : 1 - 487 OHM, 2 - 1000 OHM, 4 - 2000 OHM, 8 - 4020 OHM Voltage Rating : Overvoltage Protection: 24 VAC/VDC Current Rating : Drawn: 250 MA At 5.1 V, 125 MA At 24 V Isolation : 250 V (Continuous), Basic Insulation Type, Input Channels-To-Backplane, And Input Channel-To-Channel, 1350 VAC For 2 SEC Routine Test Power Rating: Backplane : 4.25 W Enclosure : Open Type Rfi Suppression : Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ On Shielded Signal Ports Display : Module Health, In Calibration Mode Interface : Removable Terminal Block, IEEE Mounting : Chassis Width : 1-23/64 IN Height : 5-11/16 IN Temperature Rating : 32 - 140° F Environmental Conditions : Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G At 10 - 500 HZ , Shock: 30 G(Operating), 50 G (Non-Operating) Response Time : Open Circuit Detection Time: Negative Full Scale Reading Within 5 SEC With Any Combination Of Lost Wires, Except Input Terminal A Alone, If Input Terminal A Is Lost By Itself, The Module Reads A Positive Full Scale Reading Within 5 SEC, Settling Time: Less Than 80 MS To 5% Of Full Scale, Module Scan Time: 25 MS Min Floating Point, 50 MS Min Floating Point, 10 MS Min Integer Accuracy : Calibrated: Better Than 0.1% Of Range At 25°C Power Dissipation : 4.3 W Surge Transient Immunity : Plus/Minus 2 KV Line-Earth (CM) On Shielded Signal Ports Resolution : 16 Bits, 1 - 487 OHM: 7.7 MOHM/Bit, 2 - 1000 OHM: 15 MOHM/Bit, 4 - 2000 OHM: 30 MOHM/Bit, 8 - 4020 OHM: 60 MOHM/Bit Rejection Ratio : Normal Mode Noise Rejection: 60 DB At 60 HZ, Common Mode Noise Rejection: 120 DB At 60 HZ, 100 DB At 50 HZ Slot Width : 1