Catalog > Test and Measurement > Test and Measurement Instruments > Multimeters > Digital Multimeters Catalog > Test and Measurement > Test and Measurement Instruments > Fluke Instruments Fluke 1000V AC/DC Digital Multimeter 1000V AC/DC Digital Multimeter FLUKE 17B+ Digital Multimeter, 1000V AC/DC, 10A AC/DC, 40M OHM Resistance, 100KHz Frequency, 100UF Capacitance, 400D TEMP, Continuity, Diode Test 4,320.14 ZAR inc for 1 Each 3 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Overview Experience the precision, durability, and safety of a professional-grade test tool with the Fluke 17B+ Digital Multimeter. With the Fluke 17B+, you'll have a rugged, portable tool that's designed to be used with one hand, even while wearing gloves. It provides all the essential features you need in a digital multimeter, from AC/DC voltage and current measurements up to 1000V and 10A, to comprehensive capabilities including resistance, capacitance, and frequency checks. It also comes standard with a type K thermocouple so you can measure the temperature of things like your refrigeration systems, heat exchangers, and line sets. The 17B+ also supports relative measurements which allows you to zero out a source reading so you can easily measure changes in things like voltage drop or temperature making it ideal for identifying and diagnosing issues. The CAT III 600V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. If you’re looking to build out your toolkit as a DIY enthusiast or early career electrician, look no further than the Fluke 17B+ Digital Multimeter, a reliable and versatile tool that provides the essential features you need. Features 600 V Cat III safety rating AC/DC voltage measurement up to 1000V AC/DC current measurement up to 10A Measures voltage, resistance, continuity, capacitance Frequency and temperature measurement Large easy-to-read display with bright white backlight Specifications Function Range Resolution Accuracy AC volts(40 Hz to 500Hz)1 4.000 V40.00 V400.0 V1000 V 0.001 V0.01 V0.1 V1 V 1.0% + 3 DC volts 4.000 V40.00 V400.0 V1000 V 0.001 V0.01 V0.1 V1 V 0.5% + 3 AC millivolts 400.0 mV 0.1 mV 3.0% + 3 DC millivolts 400.0 mV 0.1 mV 1.0% + 10 Diode test2 2.000 V 0.001 V 10% Resistance(Ohms) 400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ 0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ 0.5% + 30.5% + 20.5% + 20.5% + 20.5% + 21.5% + 3 Capacitance3 40.00 nF400.0 nF4.000 μF40.00 μF400.0 μF1000 μF 0.01 nF0.1 nF0.001 μF0.01 μF0.1 μF1 μF 2% + 52% + 55% + 55% + 55% + 55% + 5 Frequency1 Hz(10 Hz – 100 kHz) 50.00 Hz500.0 Hz5.000 kHz50.00 kHz100.0 kHz 0.01 Hz0.1 Hz0.001 kHz0.01 kHz0.1 kHz 0.1% + 3 Duty Cycle1 1% to 99% 0.1% 1% typical 4 AC current μA(40 Hz to 400 Hz) 400.0 μA4000 μA 0.1 μA1 μA 1.5% + 3 AC current mA(40 Hz to 400 Hz) 40.00 mA400.0 mA 0.01 mA0.1 mA 1.5% + 3 AC current A(40 Hz to 400 Hz) 4.000 A10.00 A 0.001 A0.01 A 1.5% + 3 DC current μA 400.0 μA4000 μA 0.1 μA1 μA 1.5% + 3 DC current mA 40.00 mA400.0 mA 0.01 mA0.1 mA 1.5% + 3 DC current A 4.000 A10.00 A 0.001 A0.01 A 1.5% + 3 Temperature 50 °C- 400 °C0 °C- 50 °C-55 °C- 0 °C 0.1C 2% ±1 °C±2 °C9% ±2 °C Backlight - - Yes 1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%. Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,50 Hz or 60 Hz - AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz - DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz - 1 106 V Hz Max General specifications Maximum voltage between any terminal and earth ground 1000 V Display (LCD) 4000 counts, updates 3/sec Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 500 hours minimum Temperature Operating 0 °C to 40 °C Storage -30 °C to 60 °C Relative humidity Operating humidity Non-condensing (<10°C)≤90% RH at 10 °C to 30 °C≤75% RH at 30 °C to 40 °C 40 MΩ range≤80% RH at 10 °C to 30 °C≤70% RH at 30 °C to 40 °C Altitude Operating 2000 m Storage 12,000 m Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.11A, 1000V Fast Fuse, Fluke specified part only. Size (H x W x L) 183 x 91 x 49.5 mm Weight 455 g IP rating IP 40 Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2 Electromagnetic compatibility IEC 61326-1: Portable EMC Environment Class A equipment (industrial broadcasting and communication equipment)11 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller oruser should take notice of it. This equipment is intended for use in business environments and is not to beused in homes. Downloads Datasheet - FLUKE 15B/17B PDF File 375.78 KB