Omron Side Mounting Enclosed Limit Switch Snap Action Crossover Roller Plunger Side Mounting Enclosed Switch XE-Q21-2 Omron Snap Action Crossover Roller Plunger Side Mounting Enclosed Limit Switch, NO/NC, 10A/125VDC-3A/250VDC - G1/2" Cable Entry 1,018.02 ZAR inc for 1 Each 3 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Specifications Shape/Structure Enclosed Limit switches ctuator Cross roller plunger 12.7 dia. x 4.8Stainless steel roller Contact configuration SPDT (DC) Contact form SPDT Load General load Ratings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/10 A at 30 VDC/10 A at 125 VDC/3 A at 250 VDCLamp load (NC): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/3 A at 125 VDC/1.5 A at 250 VDCLamp load (NO): 1.5 A at 8 VDC/1.5 A at 14 VDC/1.5 A at 30 VDC/1.5 A at 125 VDC/0.75 A at 250 VDCInductive load (NC): 10 A at 8 VDC/10 A at 14 VDC/10 A at 30 VDC/7.5 A at 125 VDC/2 A at 250 VDCInductive load (NO): 10 A at 8 VDC/10 A at 14 VDC/10 A at 30 VDC/6 A at 125 VDC/1.5 A at 250 VDCMotor load (NC): 5 A at 8 VDC/5 A at 14 VDC/5 A at 30 VDC/2 A at 125 VDC/2 A at 250 VDCMotor load (NO): 2.5 A at 8 VDC/2.5 A at 14 VDC/2.5 A at 30 VDC/2.5 A at 125 VDC/1.5 A at 250 VDC Inrush current NC: 30 A max.NO: 15 A max. Conduit G1/2 Earth terminal No Ambient temperature Operating: -10 to 80 ℃ (with no icing) Ambient humidity 35 to 85% RH Permissible operating speed 0.01 mm/s to 0.5 m/s Permissible operating frequency Electrical: 20 operations / 1 minute max.Mechanical: 120 operations / 1 minute max. Contact resistance (Initial value) 15 mΩ max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 minBetween live-metallic part and ground: 1,500 VAC 50/60 Hz 1 minBetween each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz 1 min Durability Electrical: 100,000 operations min. (10 A at 125 VAC)Mechanical: 1,000,000 operations min. Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude at the total travel position Shock resistance Destruction: 1000 m/s2 max. (at total travel position)Malfunction: 50 m/s2 max. (at total travel position) Degree of protection IP60 Operating Force (OF) Standard value 5.0 N max. Release Force (RF) Standard value 1.12 N min. Pre-Travel (PT) Standard value 0.9 mm max. Movement Differential (MD) Standard value 0.47 mm max. Over-Travel (OT) Standard value 3.6 mm min. Operating Position (OP) Standard value 49.7±1 mm