Catalog > Test and Measurement > Test and Measurement Instruments > Multimeters > Digital Multimeters Catalog > Test and Measurement > Test and Measurement Instruments > Fluke Instruments 1000V AC/DC Electrical Tester Electrical Tester Tester FLUKE T6-1000 PRO Electrical Tester 1000V AC/DC, Resolution:1V, Freq:45hz~66hz Through Open Fork, Resistance:1ω~100kω, AC Current:0.1~200A AC, True RMS, CatIII 1000V 10,203.00 ZAR inc for 1 Each 1 in Stock Add Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE Features Save time by seeing voltage and current measurements at the same time Visual Continuity™ – the screen automatically turns green for continuity, perfect when it’s too loud to hear the beeper FieldSense™ technology for ac voltage, current and frequency, all without making electrical contact to live voltage Specifications Function FieldSense ac voltage Requires test leads No Range 1000 V Resolution 1 V Accuracy ±(3 % + 3 counts) 45 Hz - 66 Hz[1] [2] FieldSense ac current Requires test leads No Range 200.0 A Resolution 0.1 A Accuracy ±(3 % + 3 counts) 45 Hz - 66 Hz FieldSense frequency (Hz) Requires test leads No Range 45 Hz – 66 Hz Resolution 1 Hz Accuracy ±(1 % + 2 counts) Volts ac Requires test leads Yes Range 1000 V Resolution 1 V Accuracy ±(1.5 % + 2 counts) 45 Hz - 66 Hz Volts dc Requires test leads Yes Range 1000 V Resolution 1 V Accuracy ±(1 % + 2 counts) Resistance Requires test leads (all ranges) Yes Range 2000 Ω Resolution 1 Ω Range 20.00 kΩ Resolution 0.01 kΩ Range 100.0 kΩ Resolution 0.1 kΩ Accuracy (all ranges) ±(1 % + 2 counts) Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding. Accuracy[2]: FieldSense specified from 16V to 1000V. General Specifications Calibration 1-year calibration cycle Dimensions 61 mm x 259 mm x 43 mm Weight 0.35 kg (0.78 lb) Fork opening 17.8 mm (0.7”) TemperatureOperating:Storage: -10 °C to +50 °C (14 °F to 122 °F)-30 °C to +60 °C (-22 °F to +140 °F) AltitudeOperating:Storage: 2,000 m (6,562 feet)10,000 m (32,808 feet) Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F) BatteryType:Life: 2x AA (IEC LR6)360 hour continuous, typical is 200 hour using the FieldSense function Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F) SafetyGeneral:MeasurementT6-1000 PRO: IEC 61010-1: Pollution Degree 2IEC 61010-2-032: CAT IV 600 V / CAT III 1000 V Electromagnetic Compatibility IEC/EN 61326-1: Portable Downloads Datasheet PDF File 456.16 KB