Fluke 789 Specifications |
Current measurement |
Range |
0-1 A AC or DC |
Resolution |
1 mA |
Accuracy |
0.2% + 2 LSD (DC) |
Range |
0-30 mA |
Resolution |
0.001 mA |
Accuracy |
0.05% + 2 lSD |
Current sourcing |
Range |
0-20 mA or 4-20 mA |
Resolution |
0.05% of span |
Drive capability |
24 V Compliance or 1200 Ω @ 20 mA |
Frequency |
to 19.999 kHz, 0.005% + 1 LSD |
Continuity |
Beeps for resistance < 100 Ω |
Voltage measurement |
Range |
0-1000 V AC (true-rms) or DC |
Resolution |
0.1 mV to 1.0 V |
Accuracy |
0.1% Rdg + 1 LSD (VDC) |
Resistance measurement |
to 40 MΩ, 0.2% + 1 LSD |
Diode test |
2.0 V shoes diode voltage drop |
Display current and % of span |
Yes |
Auto Step, Auto Ramp |
Yes |
Environmental Specifications |
Operating temperature |
-20°C to 55°C |
Storage temperature |
-40°C to 60°C |
Humidity (without condensation) |
95% up to 30°C |
75% up to 40°C |
45% up to 50°C |
35% up to 55°C |
Temperature coefficient |
0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C) |
Safety Specifications |
Electrical safety |
Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 |
Overvoltage category |
IEC 1010-1 CAT III 1000 V |
IEC 1010-1 CAT IV 600 V |
Maximum voltage |
1000 V RMS |
Mechanical and General Specifications |
Size (H x W x L) |
50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) |
Weight |
610 g (1.6 lbs) |
Batteries |
4 AA alkaline batteries |
Warranty |
3 years |
Battery life |
140 hours typical (measurement), 10 hours typical (sourcing 20 mA) |
Shock and vibration |
Random, 2 g, 5-500 Hz |
1 meter drop test |