Technical specification
|
DC BLUE ASTUTE
|
Applicable door types
|
Sectional overhead and trackless tip-up doors
|
Applicable door sizes
|
<15 m2
|
Primary power supply
|
85 - 264 VAC @ 47-63
|
Rated primary power consumption
|
< 36 W
|
Motor voltage
|
24V DC
|
Maximum operations per day
|
<20 full cycles per 24 hours @ Max. 5 cycles per hour
|
Rated auxiliary output
|
< A @ 12 VDC
|
Rated battery charging voltage
|
28,8 VDC
|
Battery type compatibility
|
LiFeP04, SLA ACM, SLA GEL and SLA CRYSTAL
|
Number of operations on battery reserve without AC present
|
< 70 cycles (From a fully charged and healthy 1,5 Ah Li-lon battery)*
|
Drawbar options (Ex-stock)
|
2,2 m or 3,2 m or m
|
Maximum running distance
|
|
Traveller speed*
|
8 m/min
|
Maximum load prior to anti-crush safety sensing/governing. (Force)
|
1 000 N
|
Anti-crushing safety sensing/governing
|
Yes - As per IEC SANS Safety Regulations
|
Safety beam input
|
Yes - Smart EOL monitored
|
Receiver format
|
ET BLU MIX O backward compatible with ET BLUE O - Rolling code
|
Receiver frequency
|
433,92 MHz
|
Receiver functions
|
BT: Open/close door, LT: Switch courtesy light on/off, Lock-out enable/disable.
|
Receiver memory capacity
|
35 users
|
All users can be allowed control of all channels
|
Yes
|
Ingress protection
|
IP20
|
Operating temperature range
|
O to 45 oc (32 O F to 113 O F)
|