Voltage DC |
Maximum voltage |
1000 V |
Accuracy |
±(0.05% + 1) |
Maximum resolution |
10 µV |
Voltage AC |
Maximum voltage |
1000 V |
Accuracy |
±(0.7% + 2) True RMS |
AC bandwidth |
20 kHz with low pass filter; 3 dB @ 1 kHz |
Maximum resolution |
0.1 mV |
Current DC |
Maximum amps |
10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(0.2% + 2) |
Maximum resolution |
0.01 µA |
Current AC |
Maximum amps |
10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(1.0% + 2) True RMS |
Maximum resolution |
0.1 µA |
Resistance |
Maximum resistance |
50 MΩ |
Accuracy |
±(0.2% + 1) |
Maximum resolution |
0.1 Ω |
Capacitance |
Maximum capacitance |
9,999 µF |
accuracy |
±(1% + 2) |
Maximum resolution |
0.01 nF |
Frequency |
Maximum frequency |
200 kHz |
Accuracy |
±(0.005% + 1) |
Maximum resolution |
0.01 Hz |
Duty cycle |
Maximum duty cycle |
99.9% |
Accuracy |
±(0.2% per kHz + 0.1%) |
Maximum resolution |
0.1% |
Temperature measurement |
–200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
80 BK temperature probe |
–40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
Conductance |
Maximum conductance |
60.00 nS |
Accuracy |
±(1.0% + 10) |
Maximum resolution |
0.01 nS |
Diode |
Range |
3 V |
Resolution |
1 mV |
Accuracy |
±(2% + 1) |
Duty cycle range |
Accuracy |
Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications |
Operating temperature |
–20 °C to + 55 °C |
Storage temperature |
–40 °C to + 60 °C |
Humidity (without condensation) |
0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
Operating Altitude |
2000 m |
Safety Specifications |
Overvoltage category |
EN 61010–1 to 1000 V CAT III, 600V CAT IV |
Agency approvals |
CE, CSA, RCM |
Mechanical and General Specifications |
Size |
201 x 98 x 52 mm (with holster) |
Weight |
355 g 624 g – with holster |
Display |
Digital |
6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
Analog |
32 segments, updates 40/sec |
Frequency |
19,999 counts, updates 3/sec at > 10 Hz |
Warranty |
Lifetime |
Battery Life |
Alkaline |
~400 hours typical, without backlight |
Shock |
1 Meter drop per IEC 61010–1:2001 |
Vibration |
Per MIL–PRF–28800 for a Class 2 instrument |