Electrical characteristics (X050):
- Operating voltage: 3V - 5 V
- Static output voltage: VCC/2
- Operating current: 13.5 mA (MAX)
- Storage temperature range: -65 °C – 165 °C
- Maximum output current (VIOUT-GND): 3 mA
- Internal bandwidth: 120 KHz
- Detection current range (A): ±50
- Linearity (mV/A): 40
- Working temperature (°C): -40 to 150
- Module size: 37mm x 18mm
- Module weight: 8.8 g
The relationship between voltage output and current input:
VOUT = VOUT(Q) + Vsens x I VOUT(Q) is the quiescent output voltage, which is VCC/2, which is the output voltage when there is no input. Vsens is a sensor-sensitive scale, also known as a coefficient. I is the current flowing from IP+ to IP-.
For example, suppose the sensor model is 050B, VCC is 5V, and I current is 10A, then the output is 5V / 2+40mV/A x10A=2.9V.
Package included:
- 1 x Linear Current Sensor Hall Current Module