Call Us Now !
Clearline Uni-Tripconnect 16A 230VAC, Built-In Delay, Generator Friendly, Max Discharge Current:8kA L-N, L-E, N-E (8/20us), Low Voltage Trip:180V(255V)RMS Peak, Number of Cycles to Trip:1-3 [CRL 12-01056]
Clearline Uni-Tripconnect 16A 230VAC, Built-In Delay, Generator Friendly, Max Discharge Current:8kA L-N, L-E, N-E (8/20us), Low Voltage Trip:180V(255V)RMS Peak, Number of Cycles to Trip:1-3 [CRL 12-01056]

CRL 12-01056

Uni-Tripconnect
Clearline Uni-Tripconnect 16A 230VAC, Built-In Delay, Generator Friendly, Max Discharge Current:8kA L-N, L-E, N-E (8/20us), Low Voltage Trip:180V(255V)RMS Peak, Number of Cycles to Trip:1-3
Part No: CRL 12-01056
747.50 ZAR
inc
for 1 Each
Specifications, Prices & Availability may change without notice. Images are for illustration purposes only. E&OE

Overview

There are many instances in areas where the quality of supply is unpredictable and lightning prone. Even when UPS/Generator equipment is installed, large fluctuations in supply voltage can damage electronic equipment. Power protection devices used at home, office and work place such as surge suppressors and stabilizers provide protection against power spikes that happens in milliseconds, mainly caused by
lightning.

The UNI-Tripconnect prevents damage from high power surges and dips (brownouts) caused by power shutdowns (loadshedding) and over- and under- voltages from unstable power. The duration of these conditions is normally longer and can be especially damaging to air conditioners, electric motors, etc., running under load, and expensive electronic equipment.

The UNI-Tripconnect unit will simply remove power from the equipment in the event of over or under voltage conditions and automatically restore power when the supply falls below acceptable limits. Surge protection and status monitoring has been included.

The single phase unit is simply inserted between the wall socket and the equipment power plug. Zero voltage switch-on has been included for smooth operation.

Features

  • Economical protection
  • Status monitoring
  • Automatic operation
  • Reduces in rush current
  • Built-in delay
  • Generator Friendly
  • Selectable delay - 10seconds or 5minutes

Specifications

Power Surge Protection

  • Nom. Input Voltage : 230VAC 50Hz
  • Max. Continuous Current : 16A
  • Max. Discharge Current : 8kA L-N, L-E, N-E (8/20us)
  • Residual Voltage : <900V
  • Response Time : <25ns
  • Input Connectors : 16A 3Pin Plug
  • Output Connectors : 16A 3Pin Socket

Tripconnect

  • Phase : Single (Sinusoid)
  • Low Voltage Trip : 180V (255V ) RMS peak
  • Low Voltage Connect : 190V (269V ) RMS peak
  • High Voltage Trip : 260V (368V ) RMS peak
  • High Voltage Connect : 250V (354V ) RMS peak
  • Connect Delay : Selectable 10 sec or 5 min
  • No. of Cycles to Trip : 1-3


Downloads

PDF File
776.20 KB

Copyright © 2024, Communica (Pty) Ltd.

Communica is a wholesale and retail distributor of semiconductors, electromechanical and passive electronic components for automotives, electronics, electrical, automation, mining and process control industries and technical and tertiary educational institutions. We also offer a large range of security and CCTV equipment, power supplies, test instruments and accessories, tools and production equipment, prototyping platforms, and hobby and educational products.