| Input voltage |
220V – 240V AC @ 50/60Hz |
| Motor voltage |
24V DC |
| Motor power supply – rated |
100W DC |
| Motor supply |
Mains driven, 150 VA thermally fused toroidal transformer |
| Maximum door width |
6.5m |
| Maximum door area |
15m² |
| Max holding capacity |
1200N |
| Maximum push/pull force |
50kgf |
| Battery backup |
Optional 2.9Ah battery backup |
| Charging rate |
870mA charging rate with built-in battery saving and testing functionality |
| Operations in standby mode |
Up to 70 depending on door size, weight, height, duration of power failure, and battery condition |
| Operator travel speed |
9m/min |
| Wireless communication |
BLE and Wi-Fi (2.4GHz) |
| Door travel adjustment |
Physical end-stops (automatic limit set) |
| Safety obstruction force system |
Built-in Hall Effect and current-sensing – adjustable in MyCentsys Pro |
| Light |
Integrated LED courtesy light |
| Autoclose |
Adjustable in MyCentsys Pro |
| Infrared safety beams |
Compatible with wired or wireless (optional but recommended) – configured in MyCentsys Pro |
| Radio receiver |
Code-hopping 433MHz |
| Receiver code storage capacity |
30 × 4-button NOVA transmitters |
| Degree of protection |
IPX0 (for interior use only) |